Abstract
It is presented here as a simple, selective, rapid, low-cost, with a wide linear range method to
simultaneously determine tyrosine and uric acid using a modified carbon paste electrode decorated
with graphene oxide and gold nanoparticles (GO/AuNPs/MCPE). In order to characterize and evaluate
the morphology and constituents of the nanostructures, X-ray diffraction spectroscopy, Transmission
electron microscopes, Dynamic light scattering, Zeta potential, electrochemical impedance
spectroscopy, and Voltammetry were employed. The current response on the surface of the modified
electrode had a dynamic linear range relationship in the concentrations of 0.14–340.00 μmol L−
1 and
0.06–141.00 μmol L−
1 for tyrosine and uric acid, respectively, and the method detection limit (MDL)
was 0.0060 μmol L−
1 and 0.0037 μmol L−
1, respectively. This modified electrode provided high stability,
sensitivity, and acceptable reproducibility for voltammetric measurements of tyrosine and uric acid
simultaneously in a biological matrix.