نویسندگان | Keyhandokht Karimi Shahri,Yasaman Rezaei Moghadam,Atiyeh Ebrahimi-Khankook,Parisa Akhlaghi,Najmeh Mohammadi |
---|---|
نشریه | Nuclear Instruments and Methods in Physics Research B |
شماره صفحات | 1-10 |
شماره سریال | 557 |
شماره مجلد | 1 |
ضریب تاثیر (IF) | 1.389 |
نوع مقاله | Full Paper |
تاریخ انتشار | 2024 |
نوع نشریه | الکترونیکی |
کشور محل چاپ | هلند |
نمایه نشریه | ISI،JCR،Scopus |
چکیده مقاله
The exposure (EBF) and energy absorption buildup factors (EABF) of different polymer composites (SiW, PHEMA-WO3, CaWO4, EWO3, BaTiO3, PbCl2) has been investigated for photon isotropic source with the energy range of 0.015–15 MeV and the penetration depth of 1–10 mean free path(mfp). Furthermore, the contribution of bremsstrahlung effect on selected polymer composites EBF has been discussed. Simulations were performed by MCNPX Monte Carlo code. Model validation was carried out by comparing theoretical uncollided flux and EBF of water with similar published data. The results indicate that EBF and EABF values are dependent on the incident photon energy and the depth of penetration. The maximum and minimum values of EBF and EABF are related to BaTiO3 and SiW, respectively. Moreover, it is observed that considering bremsstrahlung increases values, especially at energies greater than 3 MeV.
tags: Exposure buildup factor Energy absorption buildup factor Polymer composites Point isotropic source Monte Carlo simulation