| نویسندگان | _ |
| همایش | بیست و ششمین سمینار شیمی تجزیه ایران |
| تاریخ برگزاری همایش | 2019-08-25 |
| محل برگزاری همایش | دانشگاه سمنان |
| شماره صفحات | 0-0 |
| نوع ارائه | پوستر |
| سطح همایش | داخلی |
چکیده مقاله
Background: Benzimidazole pesticides are widely used before and after harvesting to prevent
fungal deterioration and persist over long periods of time in crop production. Their application
includes improving the yield of the product and also increasing the amount of fresh fruit and
vegetables. However, the presence of pesticides residues in food has a negative effect on human
health [1]. The maximum amount of Thaibendazole (TBZ) as a antifungal pesticide in fruits and
vegetables is 0.05-15 mg/kg, depending on the product [2]. Therefore, sensitive and reliable
methods are needed to monitor pesticide residues in water and food to ensure their safety.
Several methods have been reported for the extraction and measurement of TBZ [3]. One of the
most sensitive methods for measuring TBZ is fluorescence. However, a preconcentration method
is needed prior to the determination of TBZ to eliminate the effects of complex matrix and
increase the sample detection limit.
The aim of this work was to conduct a study on the micro solid phase extraction (μ-SPE) by
employing a new adsorbent for preconcentration of trace levels of TBZ prior to the determination
by spectrofluorimetry. This method reduces the amount of adsorbent, minimize the cost, and
decrease the amount of waste in the determination.
Methods: Micro solid phase extraction was carried out using functionalized Fe3O4 magnetic
nanoparticles that were synthesized, purified and functionalized according to a previous work
[4]. The adsorbent were characterized with FT-IR, SEM, EDX, and XRD. The absorbed analyte
was then back-extracted into a small volume of a green solvent and was determined by
spectrofluorimetry. Different parameters affect the extraction and determinations of the analyte
were optimized.
Results: The adsorbent could extract the TBZ from aqueous solution in five minutes and the
analyte was back extracted into 2 mL solvent with high recovery. The calibration curve was
linear in the concentration range of 1-25 μg mL-1 with the limit of quantification of 1 ng mL−1.
The present method was applied to the analysis of water and food samples with the relative
standard deviations less than 7%.
Conclusion: The combination of μ-SPE and spectrofluorimetry provided the selective
determination of trace TBZ in complex matrices. Compared to other conventional sample
preparation methods, the proposed method offers advantages, such as simplicity, ease of
operation, relatively short analysis time, and lower consumption of organic solvents. The
proposed method was applied to the analysis of TBZ in food samples with satisfactory results.