| Authors | Javad Khadem |
| Journal | Desalination |
| Page number | 1-18 |
| Serial number | 497 |
| Volume number | 1 |
| IF | 5.527 |
| Paper Type | Full Paper |
| Published At | 2021 |
| Journal Grade | ISI |
| Journal Type | Typographic |
| Journal Country | Netherlands |
| Journal Index | JCR،isc،Scopus |
| Keywords | multi, effect desalination thermal vapor compression (MED, TVC) City gas station (CGS) Energy, exergy, exergoeconomic analysis Multi, objective Pareto method |
|---|
Abstract
Due to their different capacities, power and heat production possibility, distribution in high populated areas, city
gas stations (CGS) are a good option to meet the energy for water desalination. This study is aimed at using the
waste energy of the city gas stations for producing power and fresh water. Accordingly, the exhaust heat of CGS
heater is employed in multi-effect desalination thermal vapor compression (MED-TVC) system and power is
produced using the turboexpander. A comprehensive model is developed to evaluate the performance of three
CGS with different capacities of 2.5, 5 and 11.5 based on energy-exergy-exergoeconomic analysis. In addition,
the effective parameters like Thermal Vapor Compressor (TVC) inlet temperature and pressure and first effect
outlet temperature are optimized by means of the multi-objective Pareto method. Since the operating conditions
of the stations are different, eventually Results show that considering the drinking water production, cost, exergy
efficiency and gain output ratio (GOR), MED-TVC system with two effects employed in 11.5 kg/s CGS is the
optimal system. It is also found that the optimal TVC inlet temperature and pressure as well as the first effect
outlet temperature are equal to 108 °C, 70 kPa and 81 °C, respectively.
Paper URL