| Authors | Mohammad Massinaei,,,,Yianatos Juan,, |
| Journal | Minerals Engineering |
| Page number | 272-278 |
| Serial number | 22 |
| Volume number | 22 |
| Paper Type | Full Paper |
| Published At | 2009 |
| Journal Grade | ISI |
| Journal Type | Typographic |
| Journal Country | Iran, Islamic Republic Of |
| Journal Index | JCR،Scopus |
| Keywords | Froth flotation; Flotation kinetics; Flotation bubbles; Flotation machines; Modeling |
|---|
Abstract
In this investigation the froth zone of an industrial column (4 m “diameter”×12 m “height”) in rougher circuit was characterized. Experiments were carried out at Miduk copper concentrator, Iran. Miduk is a unique copper processing plant which utilizes columns in rougher circuit. Cleaning and selectivity actions in the rougher froth were illustrated using solids and grade profiles along with RTD data. The impact of froth depth (FD) on overall rate constant (k) and k–Sb relationship was evaluated. Dependency of overall flotation kinetics on froth depth and gas velocity (Jg) was modeled by k=4.97(FD)–0.87(Jg)0.80. Froth recovery (Rf) was estimated and modeled in terms of froth residence time of slurry (FRTSlurry) as Rf=Rf,maxexp(–k×FRTSlurry). Finally, the correlation between k, Sb (indicative of the collection zone performance), and FRTSlurry (indicative of the froth zone performance) was modeled by k=0.02 (FRTSlurry)–0.62(Sb)0.82.
Paper URL