Effect of resilient architecture in an ancient windmill in the Sistan region on natural ventilation enhancement

نویسندگانS. Alireza Zolfaghari,Elham Mohammadi,Mohammadreza Jarkeh,Vahid Arbabi
نشریهScientific Reports
شماره صفحات1-19
شماره سریال12
شماره مجلد18240
ضریب تاثیر (IF)4.259
نوع مقالهFull Paper
تاریخ انتشار2022
نوع نشریهالکترونیکی
کشور محل چاپایران
نمایه نشریهJCR،Scopus

چکیده مقاله

Over centuries different elements have been developed in architectures for ensuring adequate natural ventilation in residential units. This study assesses the different components of an ancient windmill in Sistan, Iran, on the structure's indoor air quality (IAQ) enhancement. Several climatic scenarios have been defined by the wind analysis of Sistan meteorological data and analyzed by CFD. The site measurements confirm the accuracy of the simulation results. In the windmill, two deflectors facing the prevailing wind are the significant elements which, in addition to directing wind toward the entrance, could form vortices near the east and west openings leading to suction ventilation. Alteration of the wind speed and angle from 10 to 15 m/s and 30° to 17° would increase the air change per hour (ACH) by 150% and 110%, respectively. Meanwhile, the ACHs were higher than the ASHRAE desired level (ACH > 0.35).

لینک ثابت مقاله

tags: resilient architecture, windmill, natural ventilation